K 10 svn:author V 7 yongari K 8 svn:date V 27 2010-10-23T21:25:50.216499Z K 7 svn:log V 388 Apply the same workaround for SDI flow control used on BCM5906 A1 to BCM6906 A0/A2. This should fix a long standing BCM5906 A2 lockup issues. Data sheet explicitly mentions BCM5906 A0, A1 and A2 use de-pipelined mode on these revisions. Special thanks to Buganini who tried all combinations of experimental patches for more than 10 days. Tested by: Buganini gmail dot com > END