K 10 svn:author V 4 neel K 8 svn:date V 27 2014-10-09T19:02:32.258729Z K 7 svn:log V 384 iasl(8) expects integer fields in data tables to be specified as hexadecimal values. Therefore the bit width of the "PM Timer Block" was actually being interpreted as 50-bits instead of the expected 32-bit. This eliminates an error message emitted by a Linux 3.17 guest during boot: "Invalid length for FADT/PmTimerBlock: 50, using default 32" Reviewed by: grehan MFC after: 1 week END