K 10 svn:author V 2 ed K 8 svn:date V 27 2016-12-14T12:56:58.014056Z K 7 svn:log V 660 Add labels to sysctls related to clocks. Sysctls like kern.eventtimer.et.*.quality currently embed the name of the clock device. This is problematic for the Prometheus metrics exporter for two reasons: - Some of those clocks have dashes in their names, which Prometheus doesn't allow to be used in metric names. - It doesn't allow for extracting the same property of all clocks on the system from within a single query. Attach these nodes to have a label, so that the Prometheus metrics exporter gives these metric a uniform name with the name of the clock attached as a label. Reviewed by: cem Differential Revision: https://reviews.freebsd.org/D8775 END