K 10 svn:author V 3 avg K 8 svn:date V 27 2019-10-30T15:15:53.622804Z K 7 svn:log V 687 ow(4): increase regular mode recovery time, t_rec, to 15 us Previously we used the minimal value of 1 us and it was really tight. Application Note 3829 has a table describing recommended t_rec values for various bus voltages, temperature conditions and numbers of slave devices. The new value decreases the maximum possible data rate from 16.3 Kbit/s to 13.3 Kbit/s, but it allows for up to four slaves on a 3.3V bus (under room temperature). References: - Maxim Integrated Application Note 3829 Determining the Recovery Time for Multiple-Slave 1-Wire(R) Networks - Maxim Integrated Application Note 937 Book of iButton Standards Discussed with: imp (D22108) MFC after: 3 weeks END